Foundation Repair in FL and GA, including Jacksonville, Pensacola & Tallahassee.
Commercial Push Pier Installation in Lake City

Commercial Push Pier Systems

The Foundation Supportworks Push Pier System utilizes high-strength round steel tubes and a load transfer bracket (retrofit foundation repair bracket) to stabilize and/or lift sinking or settling foundations. The foundation bracket is secured against the existing footing and pier sections are driven hydraulically through the foundation bracket and into the soil below using the combined structural weight and any contributory soil load as resistance. Pier sections are continuously driven until a suitable load-bearing stratum is encountered. At that point, the structure either begins to lift or the target pressure/load is achieved. The weight of the structure is then transferred from the unstable soil, to the foundation brackets, through the piers, and to firm load-bearing soil or bedrock.

The Foundation Supportworks Push Pier System develops a factor of safety against pier settlement by the pier installation methods used and the sequence with which multiple piers are driven and then re-loaded. Piers are first driven individually using the maximum weight of the structure and any contributory soil load. After all of the piers are driven, the piers are re-loaded simultaneously, and the total reaction load is distributed over the multiple pier locations. Since the average load on each pier during the load transfer operation is less than the load during pier installation/driving, a factor of safety against settlement is achieved. Typical factors of safety against pier settlement range from about 1.5 to 3.0, with higher values generally achieved for structures with greater rigidity. These factors of safety conservatively ignore any additional long-term frictional component to the pier's capacity (see below for more information).

Foundation Supportworks™ Model 288 Pier System Specifications

  • Bracket: Weldment manufactured from 0.25", 0.375", and 0.50"-thick steel plate. Yield strength = 36 ksi (min.), tensile strength = 58 ksi (min.).
  • External Sleeve: 3.50" OD x 0.216" wall x 30" or 48" long with sleeve collar welded to one end. Yield strength = 50 ksi (min.), tensile strength = 62 ksi (min.).
  • Pier Starter Tube: 2.875" OD x 0.165" wall x 50" long, triple-coated in-line galvanized. Yield strength = 50 ksi (min.), tensile strength = 55 ksi (min.). 3.375" OD x 0.188" wall x 1" long friction reducing collar welded to one end.
  • Pier Tube: 2.875" OD x 0.165" wall x 36" long, triple-coated in-line galvanized. Yield strength = 50 ksi (min.), tensile strength = 55 ksi (min.). 2.50" OD x 0.180" wall x 6" long internal coupler at one end with 3" extending out of pier tube.
  • Pier Cap: 5.0" wide x 9.0" long x 1" thick plate with confining ring welded to one side. Yield strength = 50 ksi (min.), tensile strength = 65 ksi (min.).
  • All-Thread Rod: 0.75" diameter x 16" long, zinc plated, Grade B7, tensile strength = 125 ksi [min.].

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 288 Capacity Summary

Soil Strength Parameters(2)

Allowable System Capacity(1,2,3,4,5) (kips)

Allowable System Capacity(1,2,3,4,5) (kips)

Soil Type

Consistency/
Relative Denisty

SPT, N-Value

Cohesion (psf)

Friction Angle (degrees)

48" Ext. Sleeve

30" Ext. Sleeve

Clay

Very Soft

< 2

< 250

-

23.5

19.2

Clay

Soft

2-3

250-500

- 27.0

21.5

Clay

Medium Stiff

4-7

501-1,000

-

32.0

23.9

Clay

Stiff

8-15

1,001-2,000

-

34.5

26.9

Clay

Very Stiff

16-31

2,001-4,000

-

34.5

30.8

Sand

Very Loose

< 3

-

26-30

33.0

24.2

Sand

Loose

4-9

-

28-34

33.0

24.2

Sand

Medium

10-29

-

30-36

34.0

26.3

Sand

Dense

30-39

-

34-40

34.5

27.2

(1) ‐ Retrofit brackets shall be used for support of structures that are considered to be fixed from translation. Structures that are not fixed from translation shall be braced in some other manner prior to installing retrofit bracket systems.

(2) ‐ Allowable capacities are based on continuous lateral soil confinement in soils with SPT blow counts as listed. Piles with exposed unbraced lengths or piles placed in fluid soils should be evaluated on a case by case basis by the project

(3) ‐ Allowable capacities consider a loss in steel thickness doe to corrosion. Scheduled thickness losses are for a period of 50 years and are in accordance with ICC‐ES AC358.

(4) ‐ Allowable capacities assume a concrete footing with a minimum compressive strength (f'c) = 2,500 psi.

(5) ‐ Allowable capacities with FS350BV retrofit bracket.

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 350 Pier System Specifications

  • Bracket: Weldment manufactured from 0.38”, 0.50”, and 0.63” thick steel plate, Yield strength = 36 ksi (min.), tensile strength = 58 ksi (min.).
  • External Sleeve: Ø4.000” x 0.226” wall x 48” long with sleeve collar welded to one end. Yield strength = 50 ksi (min.), tensile strength = 62 ksi (min.).
  • Pier Starter Tube:Ø3.500” x 0.165” wall x 50” long, triple-coated in-line galvanized. Yield strength = 50 ksi (min.), tensile strength = 55 ksi (min.). Ø4.000” x 0.226” wall x 1” long friction reducing collar welded to one end.
  • Pier Tube: Ø3.500” x 0.165” wall x 36” long, triple-coated in-line galvanized. Yield strength = 50 ksi (min.), tensile strength = 55 ksi (min.). Ø3.125” x 0.180” wall x 6” long internal coupler at one end with 3” extending out of pier tube.
  • Pier Cap: 4.00” wide x 8.50” long x 1.25” thick plate with pier locator plate welded to one side. Yield strength = 50 ksi (min.), tensile strength = 65 ksi (min.).
  • All-Thread Rod: Ø7/8” x 18” long, zinc plated. Grade B7, tensile strength = 125 ksi (min.).

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 350 Capacity Summary

Soil Strength Parameters(2)

Allowable System Capacity (1,2,3,4,5) (kips)

Soil Type

Consistency/Relative Density

SPT, N-value (blows/ft)

Cohesion (psf)

Friction Angle (degrees)

Clay

Very Soft

< 2

< 250

-

32.5

Clay

Soft

2-3

250-500

- 36.5

Clay

Medium Stiff

4-7

501-1,000

-

41.5

Clay

Stiff

8-15

1,001-2,000

-

43.5

Clay

Very Stiff

16-31

2,001-4,000

-

43.5

Sand

Very Loose

< 3

-

26-30

43.5

Sand

Loose

4-9

-

28-34

43.5

Sand

Medium

10-29

-

30-36

44.0

Sand

Dense

30-39

-

34-40

44.0

(1) ‐ Retrofit brackets shall be used for support of structures that are considered to be fixed from translation. Structures that are not fixed from translation shall be braced in some other manner prior to installing retrofit bracket systems.

(2) ‐ Allowable capacities are based on continuous lateral soil confinement in soils with SPT blow counts as listed. Piles with exposed unbraced lengths or piles placed in fluid soils should be evaluated on a case by case basis by the project

(3) ‐ Allowable capacities consider a loss in steel thickness doe to corrosion. Scheduled thickness losses are for a period of 50 years and are in accordance with ICC‐ES AC358.

(4) ‐ Allowable capacities assume a concrete footing with a minimum compressive strength (f'c) = 2,500 psi.

(5) ‐ Allowable capacities with FS350BV retrofit bracket.

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 400 Pier System Specifications

  • Bracket: Weldment manufactured from steel plates with integrated pipe sleeve. Steel plate: 0.38” and 0.50” thick steel plate, yield strength = 36 ksi (min.), tensile strength = 58 ksi (min.). Pipe sleeve: Ø4.50” x 0.237” wall x 14.50” long. ASTM A53 Grade B Type E & S, yield strength = 35 ksi (min.), tensile strength = 60 ksi (min.).
  • Pier Starter Tube:Ø4.00” x 0.226” wall x 36” long. ASTM A500 Grade B or C, yield strength = 50 ksi (min.), tensile strength = 62 ksi (min.). Ø4.50” x 0.237” wall x 1” long friction reducing collar welded to one end.
  • Pier Tube:Ø4.00” x 0.226” wall x 36” long. ASTM A500 Grade B or C, yield strength = 50 ksi (min.), tensile strength = 62 ksi (min.). Ø3.50” x 0.216” wall x 8” long internal coupler at one end with 4” extending out of pier tube.
  • Pier Cap: 4.00” wide x 8.50” long x 1.25” thick plate with pier locator plate welded to one side. ASTM A572 Grade 50, yield strength = 50 ksi (min.), tensile strength = 65 ksi (min.). All-Thread Rod: Ø0.875” x 18” long, zinc plated. ASTM A193 Grade B7, tensile strength = 125 ksi (min.).

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 400 Capacity Summary

Allowable System Capacity: 39,000 lbs. (with FS400BV Bracket)

Notes:

1.Retrofit brackets shall be used for support of structures that are considered to be fixed from translation. Structures that are not fixed from translation shall be braced in some other manner prior to installing retrofit bracket systems.

2.Concrete bearing assumes a minimum compressive strength (f’c) of 2,500 psi. Local concrete bending and other local design checks should be evaluated on a case by case basis by the project engineer.

3.Mechanical capacity is based on continuous lateral soil confinement in soils with SPT blow counts ≥ 4. Piles with exposed unbraced lengths or piles placed in weaker or fluid soils should be evaluated on a case by case basis by the project engineer.

-- View Our Push Pier System Product Specifications document --


Design Considerations

Push piers are installed directly adjacent to the existing structure utilizing side-load brackets. This introduces eccentricity into the system. The Model 288 Push Pier System incorporates an external sleeve at the top of the pier to aid in resisting the bending forces generated by this loading condition. This helps preserve the axial compressive capacity of the pier shaft. The external sleeve extends through and below the foundation bracket to essentially create a bracket that is 48 inches tall.

The moment or bending force is localized within a relatively short distance below the bracket. Although the bending force is dissipated quickly by the pier bearing against the confining soil, it is significant and cannot be ignored. The depth or length of sleeve and pier over which the bending force dissipates is a function of the soil stiffness near the surface. The depth is greater in soft clay and loose sand, and less in stiff clay and dense sand. In soft or loose soils, a small portion of the bending force may be transferred to the pier below the sleeve, thereby reducing the pier's allowable axial compressive capacity. A modified, lower capacity system is also available with a shorter, 30-inch long sleeve for low headroom applications.

Friction Reducing Collar

The first pier section advanced into the ground includes a larger-diameter "friction reducing collar" welded to the lead end. This collar, being larger in diameter than the pier tube, effectively creates annular space around the pier as it is advanced through most clayey soils. In soft clay or clean sand and gravel, an annular space may only temporarily be created. However, the larger diameter collar causes soil disturbance or remolding to occur, which also significantly reduces frictional resistance on the outside surface of the pier during driving. The result is a driven pier that generates most of its capacity in end bearing. Over time, the soils surrounding the pier relax back into the annular space and against the pier shaft. This provides an additional frictional component to the pier's capacity. Even though this frictional capacity may be significant, it is conservatively ignored in the determination of the pier's factor of safety against pier settlement.

Reviews
Testimonials

Your company exceeded our expectation - you were timely, thorough and within our agreed to budget.
Testimonial by Keith from Killearn Lakes, FL

Your crew was very efficient, knowlegable and easy to deal with. I would highly recommend Alpha Foundations to anyone.
Testimonial by Felicia from Milton, FL

Serving FL and GA including the Greater Jacksonville area
Our Florida and Georgia Service Area
Cities in Baldwin County, AL
Lillian

Cities in Alachua County, FL
Alachua
Earleton
Gainesville
Hawthorne
High Springs
Newberry
Waldo

Cities in Baker County, FL
Glen Saint Mary
Macclenny
Sanderson

Cities in Bay County, FL
Fountain
Lynn Haven
Panama City
Panama City Beach
Youngstown

Cities in Bradford County, FL
Brooker
Hampton
Lawtey
Starke

Cities in Calhoun County, FL
Altha
Blountstown
Clarksville
Wewahitchka

Cities in Clay County, FL
Fleming Island
Green Cove Springs
Keystone Heights
Middleburg
Orange Park

Cities in Columbia County, FL
Fort White
Lake City
Lulu

Cities in Dixie County, FL
Cross City
Horseshoe Beach
Old Town

Cities in Duval County, FL
Atlantic Beach
Jacksonville
Jacksonville Beach
Neptune Beach

Cities in Escambia County, FL
Cantonment
Century
Mc David
Molino
Pensacola

Cities in Flagler County, FL
Palm Coast

Cities in Franklin County, FL
Apalachicola
Carrabelle
Eastpoint

Cities in Gadsden County, FL
Chattahoochee
Gretna
Havana
Midway
Quincy

Cities in Gilchrist County, FL
Bell
Trenton

Cities in Gulf County, FL
Port Saint Joe
Wewahitchka

Cities in Hamilton County, FL
Jasper
Jennings
White Springs

Cities in Holmes County, FL
Bonifay
Ponce De Leon
Westville

Cities in Jackson County, FL
Alford
Bascom
Campbellton
Cottondale
Graceville
Grand Ridge
Greenwood
Malone
Marianna
Sneads

Cities in Jefferson County, FL
Lamont
Monticello

Cities in Lafayette County, FL
Day
Mayo

Cities in Leon County, FL
Tallahassee

Cities in Liberty County, FL
Bristol
Hosford

Cities in Madison County, FL
Greenville
Lee
Madison
Pinetta

Cities in Nassau County, FL
Bryceville
Callahan
Fernandina Beach
Hilliard
Yulee

Cities in Okaloosa County, FL
Baker
Crestview
Destin
Eglin Afb
Fort Walton Beach
Holt
Hurlburt Field
Laurel Hill
Mary Esther
Niceville
Shalimar
Valparaiso

Cities in Putnam County, FL
East Palatka
Florahome
Interlachen
Melrose
Palatka
San Mateo

Cities in Saint Johns County, FL
Elkton
Hastings
Ponte Vedra
Saint Augustine
Saint Johns

Cities in Santa Rosa County, FL
Gulf Breeze
Jay
Milton
Navarre

Cities in Suwannee County, FL
Branford
Live Oak
Mc Alpin
O Brien
Wellborn

Cities in Taylor County, FL
Perry
Salem
Steinhatchee

Cities in Union County, FL
Lake Butler
Raiford

Cities in Wakulla County, FL
Crawfordville
Panacea
Saint Marks
Sopchoppy

Cities in Walton County, FL
Defuniak Springs
Freeport
Miramar Beach
Santa Rosa Beach

Cities in Washington County, FL
Caryville
Chipley
Ebro
Vernon

Cities in Brooks County, GA
Barney
Dixie
Morven
Quitman

Cities in Charlton County, GA
Saint George

Cities in Clinch County, GA
Fargo

Cities in Colquitt County, GA
Hartsfield
Moultrie

Cities in Cook County, GA
Adel

Cities in Decatur County, GA
Attapulgus
Bainbridge
Brinson
Climax

Cities in Echols County, GA
Statenville

Cities in Grady County, GA
Cairo
Whigham

Cities in Lowndes County, GA
Hahira
Lake Park
Valdosta

Cities in Miller County, GA
Colquitt

Cities in Mitchell County, GA
Camilla
Pelham
Sale City

Cities in Seminole County, GA
Donalsonville
Iron City

Cities in Thomas County, GA
Boston
Coolidge
Meigs
Ochlocknee
Pavo
Thomasville

Please call us at: 1-866-618-9710